Lexis Careers › Architecture › Unit 07 › Lesson 01

Does This Comply?

B2 Code & Compliance
About this lesson ▾

Unit 6 was about imposing an obligation. This unit is about proving you have met one — and about reading the obligations a city imposes back on you.

XP 0 Streak 0 First-try —
Lesson progress0%
01
Warm-up · 5 min

The last correction you received

Think of the last time a plan checker came back with a comment about compliance — not a drafting error, but “this does not meet the requirement.”

  • What was the requirement?
  • Did you agree, or did you think they had misread the drawing?
  • How did you answer — in writing, or by changing the design?
Teacher note Listen for whether she frames compliance as “what I am allowed to do” or as “what I can demonstrate.” The second framing is the one this unit builds, and most designers arrive with the first.
02
Input & Noticing · 10 min

Same house, three cities, three codes

The project-information blocks from three of your own sets, side by side.

Project information, as it appears on your sheets

ProjectZoningLot areaArea of workConstruction typeOccupancy
Vancouver Ave., BurlingameR16,100 sq. ft.3,700 sq. ft.Type VR-3
Wooster Ave., BelmontR1B5,158 sq. ft.2,900 sq. ft.Residential Tier 1R-3
Colonial Ln., San JoseR1-812,170 sq. ft.2,500 sq. ft.Residential V-BR-3

Notice what is constant and what is not. All three are single-family residential — the same kind of building, the same kind of work. Occupancy group is R-3 in all three, because that comes from the state code. But zoning is R1, R1B and R1-8, and construction type is written three different ways.

Zoning is local. Occupancy is state. Getting that distinction wrong is how you end up citing the wrong authority in a compliance argument — and a planner who spots it stops trusting the rest of your numbers.

03
Focus on Form · 8 min

The shape of a compliance argument

Three moves, always in this order

MoveDoes whatExample
1 · RequirementStates the rule and where it comes fromThe rear setback is 15 feet.
2 · EvidenceGives the number from your own drawingThe proposed wall sits 18 feet from the rear property line.
3 · ConclusionSays explicitly that they meetThe design therefore complies.

The move designers skip is the third. It feels redundant — the numbers speak for themselves. They do not. A plan checker reading forty sets a week is looking for the sentence that says “therefore this complies,” and if it is not there they will either work it out themselves or, more likely, write you a comment asking you to confirm it.

Stating the conclusion is not padding. It is the whole point of the paragraph.

Comparing against a limit

The verbs that carry a compliance conclusion. Listen and repeat.

04
Diagnostic Practice · 12 min

What do you already control?

Lexical Matching

Match each term to what it actually governs. Click the term, then its meaning.

Local rules on what may be built on a lot and where — set by the city, not the state
The minimum distance a structure must sit back from a property line
Any surface water cannot soak through — usually capped as a share of the lot
The state code’s classification of how a building is used — R-3 for a single-family home
Formal permission to depart from a zoning rule in a specific case
The permit has passed its last inspection and the job is formally closed
Teacher note If she is shaky on finaled, flag it — it appears on her own stamped permit (“THIS PROJECT MUST BE FINALED BY”) and carries a deadline with real consequences for the client.
MCQ Reading

Choose the best answer.

1. Your existing impervious surface is 2,963 SF and your proposed is 1,209 SF. What have you done?

2. A planner asks whether the design complies with the rear setback. Which answer is complete?

3. Occupancy group R-3 appears identically on all three of your sets because…

4. Which sentence would a plan checker find easiest to verify?

05
Baseline Performance · 15 min

Argue one compliance point

Your Day One marker for this unit.

Task card

Your Silverwood Drive project. The planner asks about impervious surface.

Using only the numbers below, argue in writing that the design complies. No preparation, no template.

  • Existing: aggregate concrete front entry 593 SF · asphalt driveway 1,318 SF · lower patio, staircases and landing 667 SF · flagstone patio 332 SF · aggregate concrete bedroom entry 53 SF
  • Proposed: MSI Atlantic Blue paver — patio, landing, staircase 1,119 SF · artificial turf 90 SF
  • Four to six sentences. Keep it.
Teacher note Do not tell her the totals — adding them up is part of the task, and whether she states totals at all is diagnostic. Note whether she reaches a stated conclusion or stops after the numbers. Most stop.
06
Feedback & Reflection · 5 min

Did you conclude?

  1. Did you write a sentence that actually says the design complies — or did you stop at the numbers?
  2. Did you give the totals, or only the line items?
  3. Did you give the percentage? Would it have helped?
07
Wrap-up · 5 min

Before the next lesson

Homework. Find the approval stamp on your Wooster Avenue set — the block the City of Belmont printed onto the drawing. Read every line of it. Bring one line you do not fully understand.